Documentation

HIMax


The following details are available for your information:

System documentation
Product Catalog
System Manual
Safety Manual
Communication Manual
Maintenance Manual
Checklists
X-BASE PLATE
X-FAN Manual
Software
SILworX
X-OPC Server
Central Modules
Type Description SIL Channels
X-CPU 01 Processor Module 4 x RJ-45 3 -
X-SB 01 System Bus Module 3 -
X-COM 01 Communication Module 4 x RJ-45, 2 x 9-pole D-Sub, up to 6 different protocols
GSD file for PROFIBUS
X-COM 01 OS V3.x GSDML Datei für PROFINET
X-COM 01 OS V4.x GSDML Datei für PROFINET
3* -
* In conjunction with safety-related protocol
Digital Input Modules
Type Description SIL Channels
X-DI 64 01 24 VDC, SIL 3 3 64
X-DI 64 51 24 VDC - 64
X-DI 32 01 24 VDC, SIL 3 3 32
X-DI 32 02 8.2 VDC, Proximity Switch, Line Monitoring, SIL 3 3 32
X-DI 32 03 48 VDC, SIL 3 3 32
X-DI 32 04 24 VDC, SOE, SIL 3 3 32
X-DI 32 05 8.2 VDC, Proximity Switch, Line Monitoring, SOE, SIL 3 3 32
X-DI 32 51 24 VDC - 32
X-DI 32 52 8.2 VDC, Proximity Switch, Line Monitoring - 32
X-DI 16 01 120 VAC, SIL 3 3 16
Analog Input Modules
Type Description SIL Channels
X-AI 32 01 4...20 mA, Line Monitoring, SIL 3 3 32
X-AI 32 02 4...20 mA, Line Monitoring, SOE, SIL 3 3 32
X-AI 32 51 0/4...20 mA, Line Monitoring - 32
X-AI 16 51 0/4...20 mA, ±280 mV, galvanically isolated, TC, Pt100, SIL 1 1 16
Counter Modules
Type Description SIL Channels
X-CI 24 01 0...20 kHz, SIL 3 3 24
X-CI 24 51 0...20 kHz - 24
Digital Output Modules
Type Description SIL Channels
X-DO 32 01 24 VDC, 0.5 A, Short-Circuit Monitoring LS, Individual Channel Shut-Off, SIL 3 3 32
X-DO 32 51 24 VDC, 0.5 A, Protected Outputs, Group Shut-Off - 32
X-DO 24 01 24 VDC, 0.5 A, Line Monitoring LS/LB, Individual Channel Shut-Off, SIL 3 3 24
X-DO 24 02 48 VDC, 0.5 A, Line Monitoring LS/LB, Individual Channel Shut-Off, SIL 3 3 24
X-DO 12 01 230 VAC/DC, Current Measurement, Cycle Counting, SIL 3 3 12
X-DO 12 02 24 VDC, 2 A, Short-Circuit Monitoring LS, Individual Channel Shut-Off, SIL 3 3 12
X-DO 12 51 Relay Output Module, 230 VAC/DC - 12
Analog Output Modules
Type Description SIL Channels
X-AO 16 01 4...20 mA, pairwise galvanically isolated, SIL 3 3 16
X-AO 16 51 0/4...20 mA - 16
Modules general
Type Description
Alle Module dimensions (HxWxD): 310 x 29 x 230 mm
Field Termination Assembly
Type Description Channels
X-FTA 001 01L Single construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04, X-DI 32 51 32
X-FTA 001 02L Redundant construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04 32
X-FTA 002 01L 01R Single construction, designed for X-DI 32 01, X-DI 32 02, X-DI 32 03, X-DI 32 04, X-DI 32 05, X-DI 32 51, X-DI 32 52, X-AI 32 01, X-AI 32 02, X-AI 32 51, X-AI 16 51, X-CI 24 01, X-CI 24 51, X-DO 32 01, X-DO 32 51, X-DO 24 01, X-DO 24 02, X-AO 16 01, X-AO 16 51 32
X-FTA 002 02L 02R Redundant construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04, X-CI 24 01, X-DO 32 01, X-DO 24 01, X-DO 24 02 32
X-FTA 003 02L 02R Redundant construction, designed for X-DI 64 01, X-DI 64 51 64
X-FTA 005 02L Redundant construction, designed for X-DO 12 01, X-DO 12 51 12
X-FTA 006 01L Single construction, designed for X-DO 12 02 12
X-FTA 006 02L Redundant construction, designed for X-DO 12 02 12
X-FTA 007 02L Redundant construction, designed for X-AI 32 01, X-AI 32 02 32
X-FTA 008 02L Redundant construction, designed for X-DI 32 02, X-DI 32 05 32
X-FTA 009 02L Redundant construction, designed for X-AO 16 01 8/16
Certifikates/Declarations of conformity
TÜV Certifikate
TÜV Report
TÜV Revision List
TÜV CENELEC SIL4 Certifikate
Achilles Certifikate
Bureau Veritas Certificate
FM Certificate USA
FM Certificate Canada
HIMax Russia GOST R Certificate

Ex solution for hazardous areas
MTL motherboard for HIMax
Catalogue
Data sheet
More information about the MTL 4500 series please find on www.MTL-inst.com
P+F motherboard for HIMax
Cable_AI3201_HIDTB16
AI3201_HIDTB32
DI3201_HICTB32
DO3201_HICTB32