Skip navigation
Other products
Components for every purpose
Complete program

Individual components and systems

As a complete provider, HIMA supports you in all functional safety questions. And these questions can be very individual. Consequently, we have a variety of components in the portfolio with which you can precisely tailor your safety systems to your requirements. If your requirement should change, simply adapt your system.

An overview of HIMA relays is provided here. All components meet the requirements of the current norms and standards and are TÜV-tested.

TypeSIL 2SIL 3(Ex)Comment
H 4116  x

 

In the terminal box for DIN rail, 24 V DC, switching voltage 250 V AC / 127 V DC, safe isolation
H 4133In the terminal box for DIN rail, 24 V DC, switching voltage 250 V AC
H 4134xIn the terminal box for DIN rail, 230 V AC, switching voltage 250 V AC
H 4135AxIn the terminal box for DIN rail, 24 V DC, switching voltage 250 V AC / 220 V DC, safe isolation
H 4136xIn the terminal box for DIN rail, 48 V DC, switching voltage 250 V AC / 127 V DC, safe isolation

Ex-switching amplifier

These components are suitable for use in explosion protection zones.

TypeSIL 3SIL 4(Ex) iComment
H 4007xxxIn the terminal box for DIN rail, switching amplifier (Ex)i, for controlling intrinsically safe valves and supplying intrinsically safe transmitters, output 24 V DC, ATEX
H 4011xxIn the terminal box for DIN rail, switching amplifier (Ex)i, safety-related, with galvanic isolation, with short-circuit monitoring, for safety-tested proximity switches
H 4012xxIn the terminal box for DIN rail, switching amplifier (Ex)i, safety-related, with galvanic isolation, with line-break and short-circuit monitoring, for safety-tested proximity switches

Ex-HART devices

These components are suitable for use in explosion protection zones.

TypeSIL 3(Ex) iComment
H 6200AxxAnalog supply isolator with HART output coupling, ATEX
H 6210xHART multiplexer, ATEX

Here you will find all power supply components at a glance.

TypeComment
H 7013Line filter 24 V DC
H 7021Line filter 48 V DC
H 7201Infeed and fuse distribution board
H 7202Fuse distribution board
K 7205Current distribution board, max. 63 A, 18 individual circuits with automatic circuit breakers
K 7206Redundant infeed, max. 63 A, with decoupling
K 7207Diode on cooling fins, for mounting rail installation
K 7212Redundant infeed, max. 35 A, with decoupling, max.12 individual circuits with automatic circuit breakers
K 7213Redundant infeed, max. 35 A, with decoupling, max.12 individual circuits with automatic circuit breakers, without decoupling
K 7214Current distribution board, 24/48 V DC, max. 150 A sum current, max. 18 individual circuits
K 7215Current distribution board, 24/48 V DC, max. 150 A sum current, max. 18 individual circuits, extensive monitoring functions
K 7216Current distribution board, 48 V DC, max. 63 A sum current, max. 32 individual circuits (micro-fuse holder 5x20 mm)
K 7901Current distribution board, 24/48 V DC, max. 63 A sum current, max. 18 individual circuits
K 7915Fuse distribution board for safety fuses 15 A, FM certificate
M 3421Rack for up to three power supply units
PS 1000/230 01Power supply unit 230 V AC, 24 V DC, 40 A continuous load
PS 1000/230 02Power supply unit 230 V AC, 48 V DC, 20 A continuous load
PS 1000/115 01Power supply unit 115 V AC, 24 V DC, 40 A continuous load
PS 1000/115 02Power supply unit 115 V AC, 48 V DC, 20 A continuous load
z6015Line filter for network supply 24 V DC
z6016Voltage failure bridging for network supply 24 V DC, 2 A, 20 ms
z6019Line filter for network supply 48 V DC

All HIMA accessory components are provided here.

TypeComment
CatalogControl cabinets and power supplies HI 800 054
IP 42 Extension kit – IP 42 for roof fan K 9202
K 9202B Cabinet fan unit with two axial fans, with fan-run monitor
K 9203AInsert fan unit with three axial fans, with fan-run monitor
K 9212Axial fan module for installation in the rack
M 2215Cover panel for H41q/H51q and Planar F in the 19-inch system in accordance with DIN EN 60297-3
M 3410-M 3419Rack in the 19-inch system in accordance with DIN EN 60297-3, pre-wired
M 3431-M 3434Front panels in the 19-inch system in accordance with DIN EN 60297-3
M 3443, M 3445Labeling fields with cable conduit carrier in the 19-inch system in accordance with DIN EN 60297-3
M 3444Labeling field with fastening angle brackets in the 19-inch system in accordance with DIN EN 60297-3
M 3446Cable tray for line routing in the 19-inch system in accordance with DIN EN 60297-3
M 3447Labeling field with three guide rings in the 19-inch system in accordance with DIN EN 60297-3
M 4410Extension kit for rack in the 19-inch system in accordance with DIN EN 60297-3
M 4411Perforated plate in the 19-inch system in accordance with DIN EN 60297-3
M 4412Cable carrier for M 3420 and M 3421
M 4413Dummy front panel for rack M 3420 and M 3421, 4U, 28HP
M 7201Ventilation tray for 19-inch system in accordance with DIN EN 60297-3, 1U
M 7202Ventilation tray for 19-inch system in accordance with DIN EN 60297-3, 1U with labeling field

 

 

Obsolete-products

Obsolete-products are only still available for a limited time. After the discontinued product life-phase, the product becomes an obsolete product and is no longer available (End-of-Life).

A list of all HIMA discontinued and obsolete-products can be requested here.

Your HIMA Contact

HIMA Support
+49 (0) 6202 709 0

Do you need support with your HIMA system? The HIMA support organization is ready at any time – an email suffices.