Detailed Information HIMax

All detailed product documentation and downloads can be accessed via our extranet.

Certificates
TÜV Certificate - Functional Safety
TÜV EC Type Examination Certificate - Machinery Directive
TÜV Revision List HIMax System
TÜV CENELEC SIL 4 Certificate - Railway
TÜV ATEX 7683 U Certificate - Gas Detectors
TÜV NRTL Certificate - Functional Safety
Achilles Certificate - Industrial Cyber Security
Bureau Veritas Certificate - Shipping
DNV Type Approval Certificate - Shipping
Lloyd's Register Type Approval - Shipping
Underwriters Laboratories Inc. UL 508 Certificate
FM Approvals Certificate USA
FM Approvals Certificate Canada
FDT HART IP Communication Certificate
Russia GOST R Certificate
Russia GOST R Ex-Certificate
Russia Pattern Approval
P+F Motherboard for HIMax
HiCTB16-HIM-RAC-SP-AO1601
HiCTB16-HIM-RAC-SP-DI3202
HiCTB16-HIM-RAC-SP-DI320X
HiCTB32-HIM-RAC-SP-AI320X
HiCTB32-HIM-RAC-SP-DI3202
HiCTB32-HIM-RAC-SP-DI320X
HiCTB32-HIM-RAC-SP-DO3201
HiCTB32-HIM-RAS-SP-AI320X
HiCTB32-HIM-RAS-SP-DI3202
HiCTB32-HIM-RAS-SP-DI320X
HiDTB16-HIM-NLC-SP-AI3201
HiDTB16-HIM-RAC-SP-AI320X
HiDTB16-HIM-RAC-SP-DO3201
Software
SILworX
X-OPC Server

System Components

Type Description SIL Channels
X-CPU 01 HIMax processor module for high performance requirements and critical control applications 3 -
X-CPU 31 HIMax processor module for small and mid-size safety applications 3 -
X-SB 01 System Bus Module 3 -
X-COM 01 Communication Module 4 x RJ-45, 2 x 9-pole D-Sub, up to 6 different protocols
PROFIBUS GSD
PROFINET GSDML, Use only for F-Modules > 8Byte
PROFINET GSDML NEW, Restriction F-Modules <= 8Byte
3* -
X-BASE PLATE 01 Base Plate for X-SB 01    
X-BASE PLATE 31 Base Plate for X-CPU 31    
X-FAN System fan    
* In conjunction with safety-related protocol

Digital Input Modules

Type Description SIL Channels
X-DI 64 01 24 VDC, SIL 3 3 64
X-DI 64 51 24 VDC - 64
X-DI 32 01 24 VDC, SIL 3 3 32
X-DI 32 02 8.2 VDC, Proximity Switch, Line Monitoring, SIL 3 3 32
X-DI 32 03 48 VDC, SIL 3 3 32
X-DI 32 04 24 VDC, SOE, SIL 3 3 32
X-DI 32 05 8.2 VDC, Proximity Switch, Line Monitoring, SOE, SIL 3 3 32
X-DI 32 51 24 VDC - 32
X-DI 32 52 8.2 VDC, Proximity Switch, Line Monitoring - 32
X-DI 16 01 110 VDC or 48/120 VAC 3 16

Counter Modules

Type Description SIL Channels
X-CI 24 01 0...20 kHz, SIL 3 3 24
X-CI 24 51 0...20 kHz - 24

Analog Input Modules

Type Description SIL Channels
X-AI 32 01 A 4...20 mA, Line Monitoring, SIL 3 3 32
X-AI 32 02 4...20 mA, Line Monitoring, SOE, SIL 3 3 32
X-AI 32 51 0/4...20 mA, Line Monitoring - 32
X-AI 16 51 0/4...20 mA, ±280 mV, galvanically isolated, TC, Pt100, SIL 1 1 16

Digital Output Modules

Type Description SIL Channels
X-DO 32 01 24 VDC, 0.5 A, Short-Circuit Monitoring LS, Individual Channel Shut-Off, SIL 3 3 32
X-DO 32 51 24 VDC, 0.5 A, Protected Outputs, Group Shut-Off - 32
X-DO 24 01 24 VDC, 0.5 A, Line Monitoring LS/LB, Individual Channel Shut-Off, SIL 3 3 24
X-DO 24 02 48 VDC, 0.5 A, Line Monitoring LS/LB, Individual Channel Shut-Off, SIL 3 3 24
X-DO 12 01 250 VAC/DC, Current Measurement, Cycle Counting, SIL 3 3 12
X-DO 12 02 24 VDC, 2 A, Short-Circuit Monitoring LS, Individual Channel Shut-Off, SIL 3 3 12
X-DO 12 51 Relay Output Module, 250 VAC/DC - 12

Analog Output Modules

Type Description SIL Channels
X-AO 16 01 4...20 mA, pairwise galvanically isolated, SIL 3 3 16
X-AO 16 51 0/4...20 mA - 16

HART Communication Module

Type Description
X-HART 32 01 32 modems, SIL 3, X-AI 32 01, X-AI 32 02, X-AI 32 51, X-AO 16 01, X-AO 16 51
  HIMA EMUX CommDTM
  HIMA HIMax Gateway DTM

Overspeed Trip Module for TMC

Type Description
X-MIO 7/6 01 3 counter, 4 digital input, 5 digital output, 1 relay channel, SIL 3

Field Termination Assembly

Type Description Channels
X-FTA 001 01L Single construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04, X-DI 32 51 32
X-FTA 001 02L Redundant construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04 32
X-FTA 002 01L 01R Single construction, designed for X-DI 32 01, X-DI 32 02, X-DI 32 03, X-DI 32 04, X-DI 32 05, X-DI 32 51, X-DI 32 52, X-AI 32 01, X-AI 32 02, X-AI 32 51, X-AI 16 51, X-CI 24 01, X-CI 24 51, X-DO 32 01, X-DO 32 51, X-DO 24 01, X-DO 24 02, X-AO 16 01, X-AO 16 51 32
X-FTA 002 02L 02R Redundant construction, designed for X-DI 32 01, X-DI 32 03, X-DI 32 04, X-CI 24 01, X-DO 32 01, X-DO 24 01, X-DO 24 02 32
X-FTA 003 02L 02R Redundant construction, designed for X-DI 64 01, X-DI 64 51 64
X-FTA 005 02L Redundant construction, designed for X-DO 12 01, X-DO 12 51 12
X-FTA 006 01L Single construction, designed for X-DO 12 02 12
X-FTA 006 02L Redundant construction, designed for X-DO 12 02 12
X-FTA 007 02L Redundant construction, designed for X-AI 32 01, X-AI 32 02 32
X-FTA 008 02L Redundant construction, designed for X-DI 32 02, X-DI 32 05 32
X-FTA 009 02L Redundant construction, designed for X-AO 16 01 8/16

Ex Isolation Amplifier, Solution for Explosion Protection

MTL Motherboard for HIMax
Catalogue

Data sheet

More information about the MTL 4500 series please find on www.MTL-inst.com